Model  | FS-N40  | |||
Type  | Zero Line Type  | |||
Main unit/expansion unit  | Expansion unit  | |||
Response time  | 23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)  | |||
Number of control outputs  | None*3  | |||
Light source LED  | Transmitter side: Red, four-element LED (wavelength: 660 nm)  | |||
External input  | Input time: 2 ms (ON) /20 ms (OFF) or longer*4  | |||
Unit expansion  | Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.  | |||
Protection circuit  | Protection against reverse power connection, output overcurrent, output surge, and reverse output connection  | |||
Mutual interference prevention  | S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)  | |||
Power supply  | Power voltage  | 10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5  | ||
Power consumption  | During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)  | |||
Environmental resistance  | Ambient light  | Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less  | ||
Ambient temperature  | -20 °C -4 °F to +55 °C +131 °F (no freezing)*7  | |||
Vibration resistance  | 10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes  | |||
Shock resistance  | 500 m/s2; 3 times each for X, Y, and Z axes  | |||
Case material  | Main unit and cover: polycarbonate  | |||
Weight  | Approx. 23 g  | |||
*1 Restrictions when S-HSPD is selected  | ||||
- USD
 - CNY
 - HKD
 - EUR
 
- العربية
 - čeština
 - dansk
 - Deutsch
 - Ελληνικά
 - English
 - Español
 - Français
 - ic
 - Italiano
 - Netherlands
 - norsk Språk
 - język polski
 - pt
 - Português
 - 中文
 
            
                    FS-N41C
Subscribe to get pricesModel: FS-N41C
Order No: FS-N41C
SKU: 10000006714101
Condition: New Sealed Under Guarantee
Size: 11.20 cm,10.60 cm,2.40 cm
Weight: 0.05kg
Product Selection Engineer:Lan
Brief Introduction
FS-N41C
ModelFS-N40TypeZero Line TypeMain unit/expansion unitExpansion unitResponse time23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)Number of control outputsNone*3Light source LEDTransmitter side: Red, four-element LED (wavelength: 660 nm)External inputInput time: 2 ms (ON) /20 ms (OFF) or longer*4Unit expansionUp to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two expansion units.Protection circuitProtection against reverse power connection, output overcurrent, output surge, and reverse output connectionMutual interference preventionS-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice those shown here when Double is set.)Power supplyPower voltage10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*5Power consumptionDuring normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V)ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*6Environmental resistanceAmbient lightIncandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or lessAmbient temperature-20 °C -4 °F to +55 °C +131 °F (no freezing)*7Vibration resistance10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axesShock resistance500 m/s2; 3 times each for X, Y, and Z axesCase materialMain unit and cover: polycarbonateWeightApprox. 23 g*1 Restrictions when S-HSPD is selectedArea detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode.Output timer, Limit Detection, and Display Gain cannot be used.FULL cannot be selected for the ECO function.*2 Restrictions when HSPD is selectedDisplay Gain cannot be used.*3 This counts as 1 output when connecting multiple units to the FS-MC8N/P, NU Series.*4 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected.*5 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher.*6 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max.*7 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F.When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units.The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface.Exercise special care when installing the product in an airtight space.
Description