Brief Introduction

VUVS-L25-M32C-MD-N14-F8-1B2

Valve function2x3/2-way, monostable, closed 2x3/2-way, open, monostable 2x3/2-way, open/closed, monostable 3/2-way, closed, monostable 3/2 open, single solenoid 5/2 double solenoid 5/2-way, monostable 5/3-way, pressurised 5/3 exhausted 5/3 closed Type of actuationElectric Valve size26.5 mm Standard nominal flow rate (standardised to DIN 1343)1000 l/min ... 1300 l/min pneumatic working portG1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8 Operating voltage110V AC 120V AC 12V DC 230V AC 240V AC 24V AC 24V DC Via solenoid coil, must be ordered separately Operating pressure-0.9 bar ... 10 bar DesignPiston gate valve Poppet seat Type of resetMechanical spring Pneumatic spring Approvalc UL us - Recognized (OL) Maritime classificationSee certificate CE mark (see declaration of conformity)To EU Explosion Protection Directive (ATEX) To EU Low Voltage Directive Explosion protection certification outside the EUClass I, Div. 1 (US) Class II, Div. 1 (US) Class III, Div. 1 (US) EPL Db (IEC-EX) EPL Dc (GB) EPL Ga (IEC-EX) EPL Gb (IECEx) EPL Gc (GB) UKCA marking (see declaration of conformity)To UK EX instructions To UK regulations for electrical equipment Certificate issuing authorityDNVGL-TAA000011J ATEX category gasII 2G II 3G ATEX category dustII 2D II 3D Explosion ignition protection type for gasAEx m II T4 Ex ec IIC T4 Gc X Ex ia IIC T6, T4 Gb Ex m II T4 Ex mb IIC T6 Gb Ex nA IIC T5/T4 X Gc Explosion ignition protection type for dustEx mb tb IIIC T80°C Db Ex tb IIIC T80°C, T130°C Db IP65 Ex tc IIIC T115°C Dc X Ex tc IIIC T95°C/T105°C X Dc Explosion ambient temperature-10 °C

Description

  • Valve function2x3/2-way, monostable, closed 2x3/2-way, open, monostable 2x3/2-way, open/closed, monostable 3/2-way, closed, monostable 3/2 open, single solenoid 5/2 double solenoid 5/2-way, monostable 5/3-way, pressurised 5/3 exhausted 5/3 closed
  • Type of actuationElectric
  • Valve size26.5 mm
  • Standard nominal flow rate (standardised to DIN 1343)1000 l/min ... 1300 l/min
  • pneumatic working portG1/4 1/4 NPT QS-6 QS-8 QS-10 QS-1/4 QS-5/16 QS-3/8
  • Operating voltage110V AC 120V AC 12V DC 230V AC 240V AC 24V AC 24V DC Via solenoid coil, must be ordered separately
  • Operating pressure-0.9 bar ... 10 bar
  • DesignPiston gate valve Poppet seat
  • Type of resetMechanical spring Pneumatic spring
  • Approvalc UL us - Recognized (OL)
  • Maritime classificationSee certificate
  • CE mark (see declaration of conformity)To EU Explosion Protection Directive (ATEX) To EU Low Voltage Directive
  • Explosion protection certification outside the EUClass I, Div. 1 (US) Class II, Div. 1 (US) Class III, Div. 1 (US) EPL Db (IEC-EX) EPL Dc (GB) EPL Ga (IEC-EX) EPL Gb (IECEx) EPL Gc (GB)
  • UKCA marking (see declaration of conformity)To UK EX instructions To UK regulations for electrical equipment
  • Certificate issuing authorityDNVGL-TAA000011J
  • ATEX category gasII 2G II 3G
  • ATEX category dustII 2D II 3D
  • Explosion ignition protection type for gasAEx m II T4 Ex ec IIC T4 Gc X Ex ia IIC T6, T4 Gb Ex m II T4 Ex mb IIC T6 Gb Ex nA IIC T5/T4 X Gc
  • Explosion ignition protection type for dustEx mb tb IIIC T80°C Db Ex tb IIIC T80°C, T130°C Db IP65 Ex tc IIIC T115°C Dc X Ex tc IIIC T95°C/T105°C X Dc
  • Explosion ambient temperature-10 °C <= Ta <= +60 °C -20 °C <= Ta <= +50 °C -20°C <= Ta <= +60°C T4, T130°C: -40°C <= Ta <= +85°C T6, T80 °C: -40 °C <= Ta <= +50 °C
  • Degree of protectionIP65 IP67 With plug socket To IEC 60529
  • Exhaust-air functionWith flow control option
  • Sealing principleSoft
  • Mounting positionoptional
  • Type of pilotingPilot actuated
  • Explosion protectionClass I, Div. 1 (US) Class II, Div. 1 (US) Class III, Div. 1 (US) The information in the certificate must be observed! Zone 0 (IEC-EX) Zone 1 (ATEX) Zone 1 (IEC-EX) Zone 2 (ATEX) Zone 2 (UKEX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 22 (ATEX) Zone 22 (UKEX)
  • Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
  • Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
  • Corrosion resistance class CRC2 - Moderate corrosion stress
  • LABS (PWIS) conformityVDMA24364-B1/B2-L
  • Cleanroom classClass 6 according to ISO 14644-1
  • Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
  • Type of mountingEither: On manifold rail With through-hole
  • Breather connectionNot ducted
  • Note on materialsRoHS-compliant
  • Material housingDie-cast aluminium Painted
  • Material screwsGalvanised steel